Back to the septic review queue
Septic maintenance (pump-out): 6342 Quarry Trl
ApprovedFiled Jun 21, 2022 by Shawn Okafor, Northstar Wastewater. Filed from a phone.
Report
- Date of service
- Jun 21, 2022
- Tank size
- 1500 gal
- Compartments
- 1
- Parts this system has
- Septic tank, Drainfield or mound
- Gallons pumped
- 1428 gal
- Sludge depth
- 28 in
- Scum depth
- 4 in
- Baffles in good condition
- No
- Effluent filter
- Cleaned
- Lids and risers secure
- Yes
- Drainfield or mound: no surfacing, soggy ground or odor
- Yes
- Disposal site
- Permitted land-application site
- Repair needed
- Yes
- Repair needed: describe
- Outlet baffle missing
- Photos
- None
- I certify this report is true and that I performed or supervised the work
- Yes
Automatic checks
- License on file for Shawn Okafor, current on the service date
- All required fields present
- Address matches parcel 017-54-01105
- Sludge is over a third of a typical tank depth; check for system failure.
- Baffles reported damaged; county may require repair.
- No photos attached.
- Result: needs follow-up. The property stays on the overdue list until a passing report arrives.
Decision
Approved by J. Staff. The property's next due date is set and the owner gets a receipt.
Property
6342 Quarry Trl
Owner: Casey Wexler
Parcel 017-54-01105