Back to the septic review queue
Septic maintenance (pump-out): 3802 Fox Run Trl
ApprovedFiled Jul 17, 2026 by Jamie Pruitt, Valley Wastewater. Filed from a phone.
Report
- Date of service
- Jul 17, 2026
- Tank size
- 1000 gal
- Compartments
- 2
- Parts this system has
- Septic tank, Drainfield or mound
- Gallons pumped
- 1044 gal
- Sludge depth
- 33 in
- Scum depth
- 3 in
- Baffles in good condition
- No
- Effluent filter
- Replaced
- Lids and risers secure
- No
- Drainfield or mound: no surfacing, soggy ground or odor
- No
- Disposal site
- Permitted land-application site
- Repair needed
- Yes
- Repair needed: describe
- Cracked lid
- Photos
- 2 attached
- I certify this report is true and that I performed or supervised the work
- Yes
Automatic checks
- License on file for Jamie Pruitt, current on the service date
- All required fields present
- Address matches parcel 053-68-01172
- Sludge is over a third of a typical tank depth; check for system failure.
- Baffles reported damaged; county may require repair.
- Unsecured lids are a safety hazard.
- Surfacing, soggy ground or odor at the drainfield or mound.
- Result: needs follow-up. The property stays on the overdue list until a passing report arrives.
Decision
Approved by M. Reviewer. The property's next due date is set and the owner gets a receipt.
Property
3802 Fox Run Trl
Owner: Hayden Wexler
Parcel 053-68-01172