Back to the backflow review queue
Backflow assembly test: 750 Stone Gate Trl
ApprovedFiled Sep 21, 2026 by Jordan Wexler, Summit Plumbing & Backflow. Filed from a phone.
Report
- Date of service
- Sep 21, 2026
- Assembly type
- RP
- Serial number
- K692688
- Size
- 1
- Test gauge serial
- G-4381
- Gauge calibration date
- Aug 3, 2025
- Check valve 1
- 0.5 psid
- Check valve 1 closed tight
- No
- Check valve 2
- 3.1 psid
- Relief valve opened at
- 3.5 psid
- Result
- Fail
- I certify this report is true and that I performed or supervised the work
- Yes
Automatic checks
- License on file for Jordan Wexler, current on the service date
- All required fields present
- Address matches parcel 075-14-01336
- Test gauge calibration is more than a year old.
- Result: needs follow-up. The property stays on the overdue list until a passing report arrives.
Decision
Approved by J. Staff. The property's next due date is set and the owner gets a receipt.
Property
750 Stone Gate Trl
Owner: Alex Ashby
Parcel 075-14-01336